8 System Decommissioning User Manual
• Before dismantling the inverter, disconnect the inverter from both AC and DC
power sources.
• If there are more than two layers of inverter DC terminals, dismantle the outer
DC connectors before dismantling the inner ones.
• If the original packing materials are available, put the inverter inside them and
then seal them using adhesive tape. If the original packing materials are not
available, put the inverter inside a cardboard box suitable for the weight and size
of this inverter and seal it properly.
step 1 Refer to 5 Electrical Connection, for the inverter disconnection of all cables in reverse steps. In
particular, when removing the DC connector, use an MC4 wrench to loosen the locking parts and
install waterproof plugs.
step 2 Refer to4 Mechanical Mounting, to dismantle the inverter in reverse steps.
step 3 If necessary, remove the wall-mounting bracket from the wall.
step 4 If the inverter will be used again in the future, please refer to 3.3 Inverter Storage for a proper
conservation.
- - End
8.3 Disposal of Inverter
Users take the responsibility for the disposal of the inverter.
WARNING
Please scrap the inverter in accordance with relevant local regulations and standards
to avoid property losses or casualties.
NOTICE
Some parts of the inverter may cause environmental pollution. Please dispose of them
in accordance with the disposal regulations for electronic waste applicable at the in
stallation site.
98