117
Number of
Inverter
Maximum Wiring Distance(unit:m)
16AWG / 1.31mm
2
17AWG / 1.026mm
2
15 869 703
16 814 660
17 766 621
18 724 586
19 686 555
20 652 528
21 620 502
22 592 480
23 567 459
24 543 440
25 521 422
In case the specification of the cable used is not included in the table above, when
there is only one inverter, ensure that the line impedance of the input node is less
than 300Ω; and when there are multiple inverters connected in the daisy chain, en-
sure that the impedance is less than 300Ω/number of inverter.
10.3 Quality Assurance
When product faults occur during the warranty period, SUNGROW will provide free service
or replace the product with a new one.
Evidence
During the warranty period, the customer shall provide the product purchase invoice and
date. In addition, the trademark on the product shall be undamaged and legible. Otherwise,
SUNGROW has the right to refuse to honor the quality guarantee.
Conditions
• After replacement, unqualified products shall be processed by SUNGROW.
• The customer shall give SUNGROW a reasonable period to repair the faulty device.
Exclusion of Liability
In the following circumstances, SUNGROW has the right to refuse to honor the quality
guarantee:
• The free warranty period for the whole machine/components has expired.