EasyManuals Logo
Home>TECO>Servo Drives>JSDAP Series

TECO JSDAP Series User Manual

TECO JSDAP Series
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
5-64
Parameter
Signal
Name Setting Description
Control
Mode
0
Input contact state. NO (Normally Open).
Connecting (IG24) to inputs, enables the
selected function.
Hn601.2
DI-1
Logic State
NO/NC Selection
1
Input contact state. NC (Normally Closed).
Disconnecting (IG24) from inputs, enables
the selected function.
ALL
New setting will become effective after re-cycling the power.
Digital Inputs 2 to 12 (Hn 602 to Hn 612). Are programmable and the logic state NO/NC can also be
selected same as that shown for digital input 1. See Hn501.
Parameter Name Description
Control
Mode
Hn602
DI-2 Programmable
Hn603
DI-3 Programmable
Hn604
DI-4 Programmable
Hn605
DI-5 Programmable
Hn606
DI-6 Programmable
Hn607
DI-7 Programmable
Hn608
DI-8 Programmable
Hn609
DI-9 Programmable
Hn610
DI-10 Programmable
Hn611
DI-11 Programmable
Hn612
DI-12 Programmable
Refer to Hn601 for programmable options. ALL
Warning! If any of programmable Inputs of DI-1 ~ DI-12 are set for the same type of function
then the logic state selection ( NO or NC selection) for these inputs must be the same type.
Otherwise an Alarm will be displayed. AL-07 (Multi-function contact setting error).

Table of Contents

Other manuals for TECO JSDAP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TECO JSDAP Series and is the answer not in the manual?

TECO JSDAP Series Specifications

General IconGeneral
BrandTECO
ModelJSDAP Series
CategoryServo Drives
LanguageEnglish

Related product manuals