6-37
Display Parameter
Communication
Address
Parameter
Signal
Display Unit Explanation
RS232 RS485
Un-01
Actual Motor Speed rpm
Motor Speed is displayed in rpm.
6C4H 0601H
Un-02
Actual Motor Torque %
It displays the torque as a percentage of the rated
torue.
Ex: 20 are displayed. It means that the motor torque
output is 20% of rated torque.
9B6H 0602H
Un-03
Regenerative load rate
%
Value for the processable regenerative power as
100% .
Displays regenerative power consumption in 10-s
cycle.
6F4H 0603H
Un-04
Accumulated load rate
%
Value for the rated torque as 100%.
Displays effective torque in 10-s cyle.
693H 0604H
Un-05
Max load rate
% Max value of accumulated load rate
694H 0605H
Un-06
Speed Command rpm
Speed command is displayed in rpm.
678H 0606H
Un-07
Position Error Value pulse
Error between position command value and the
actual position feedback.
65CH 0607H
Un-08
Position Feed-back Value pulse
The accumulated number of pulses from the
encoder.
688H 0608H
Un-09
ExternalVoltage Command V
External analog voltage command value in volts.
632H 0609H
Un-10
(Vdc Bus)Main Loop
Voltage
V
DC Bus voltage in Volts.
6B7H 060AH
Un-11
External Spped Limit
Command Value
rpm
External speed limit value in rpm.
695H 060BH
Un-12
External CCW Torque Limit
Command Value
%
Ex: Display 100. Means current external CCW
torque limit command is set to 100 %.
6C0H 060CH
Un-13
External CW Torque
LimitCommand Value
%
Ex: Display 100. Means current external CW toque
limit command is set to 100%.
6C1H 060DH
Un-14
Motor feed back – Less
then 1 rotation pulse
value(Low Byte)
pulse
After power on, it displays the number of pulses for
an incomplete revolution of the motor as a
Low
Byte
value.
8FDH 060EH
Un-15
Motor feed back – Less
then 1 rotation pulse
value(High Byte)
pulse
After power on, it displays the number of pulses for
an incomplete revolution of the motor as a
High
Byte
value.
8FCH 060FH
Un-16
Motor feed back – Rotation
value (Low Byte)
rev
After power on, it displays motor rotation number as
a
Low Byte value.
8FFH 0610H
Un-17
Motor feed back – Rotation
value (absolute value)
rev
After power on, it displays motor rotation number as
a
High Byte value.
8FEH 0611H
Un-18
Pulse command – Less
then 1 rotation pulse
value(Low Byte)
pulse
After power on, it displays pulse command input for
an incomplete rotation. pulse value is a
Low Byte
value.
8F9H 0612H
Un-19
Pulse command – Less
then 1 rotation pulse
value(absolute value)
pulse
After power on, it displays pulse command input for
an incomplete rotation. pulse value is a
High Byte
value.
8F8H 0613H
Un-20
Pulse command – rotation
value(Low Byte)
rev
After power on, it displays pulse command input
rotation number in
Low Byte value.
8FBH 0614H

Table of Contents

Other manuals for TECO JSDAP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TECO JSDAP Series and is the answer not in the manual?

TECO JSDAP Series Specifications

General IconGeneral
BrandTECO
ModelJSDAP Series
CategoryServo Drives
LanguageEnglish

Related product manuals