EasyManuals Logo
Home>Tektronix>GPS>370B

Tektronix 370B User Manual

Tektronix 370B
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #170 background imageLoading...
Page #170 background image
GPIB
4-46 370B User Manual
Table 4-13: Status Byte and Event Code
Status byte Event code Meaning
System Event
00No error
65 401 Power on
66 402 Measure signal operation complete (mask OPC)
66 406 Measure sweep operation complete (mask OPC)
407 Disk format operation complete (mask OPC)
67 403 User request (FAST + SINGLE button)
68 404 Printer output complete
69 405 Collector Supply recovered
Command Error 101 Command header error
103 Command argument error
97 106 Command syntax error
108 Checksum error
109 Byte count error
Execution Error 201 Command not executable in local mode
203 Output buffer overflow;
98 remaining output lost
204 Setting conflicts
205 Argument out of range
206 Floppy I/O error
207 NR.PT byte count mis match
250 NonĆvolatile memory I/O error
Internal Error 303 PhaseĆlock system failed
99 305 Series Resistor is overheated
306 Printer fail
350 Outputs protected
307 Collector Supply short
DeviceĆ
dependent Event
750
Interlock system changed (mask OPC)
751 OUTPUTS breaker changed (mask OPC)
742 LEFTĆRIGHTĆSTANDBY switch changed (mask OPC)
753 Disk format operation complete (mask OPC)
754 Outputs resumed (mask OPC)
Event Codes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 370B and is the answer not in the manual?

Tektronix 370B Specifications

General IconGeneral
BrandTektronix
Model370B
CategoryGPS
LanguageEnglish