GPIB
4-38
370B User Manual
Table 4-10: Display Data and CRT Readout I/O
WAVEFORM TRANSFER COMMAND GROUP
Command Argument Link Definition
WFMpre <string> Load waveform preamble data.
WFMPRE WFID:<wfid>,ENCDG :BIN,
NR.PT:<point>,PT.FMT:XY, XMULT:<x multi>,
XZERO:0, XOFF:<x off>,XUNIT:V, YMULT:<y multi> ,
YZERO :0 , YOFF :<y off> ,YUN IT:A, BYT/NR:2,
BN.FMT:RP,BIT/NR:10,CRVCHK:CHKSMO,
LN.FMT: <format>
<wfid> ::=INDEX <num>/VERT<amp>/HORIZ <volt>/
STEP<step>/OFFSET<offset)/BGM<para>/
AUX<aux>/ACQ<acq>/VCS<percent>/TEXT <txt>"
<num> ::= Memory location number
<amp> ::= Vertical amps/div
<volt> ::= Horizontal volts/div
<step> ::= Step amplitude
<offset> ::= Step offset
<para> ::= Beta or gm
<aux> ::= Aux Supply
<acq> ::= Curve acquisition mode (AVG|NOR|ENV)
<percent> ::= Variable Collector Supply setting %
<txt> ::= Text area readout
<point> ::= curve point no. (1 - 1024)
<x multi> ::= <NR3>= horizontal scale factor
<x off> ::= <NR1>= horizontal scale offset
<y multi> ::= <NR3>= vertical scale factor
<y off> ::= <NR1>= vertical scale offset
<format> ::= VECTOR|DOT|SWEEP <num><num> ::=
number of steps + 1
WFMpre NR.PT <NR1> Sets input points number from curve command (1 to 1024)