MEASURES, LOGIC STATES AND COUNTERS
90
NG10 - Manual - 04 - 2022
5 MEASURES, LOGIC STATES AND COUNTERS 5 MEASURES, LOGIC STATES AND COUNTERS
Measures
Direct
Frequency (f )
RMS value of fundamental component for phase currents (I
L1
, I
L2
, I
L3
)
RMS value of fundamental component for phase currents side L (I
L1
, I
L2
, I
L3
)
RMS value of fundamental component for residual current (I
E
)
L1, L2, L3 Phases
Compensated phase currents side H (I
L1cH
, I
L2cH
, I
L3cH
)
Compensated phase currents side L (I
L1cL
, I
L2cL
, I
L3cL
)
Stabilization phase currents (I
SL1
, I
SL2
, I
SL3
)
Differential phase currents (I
dL1
, I
dL2
, I
dL3
)
Calculated
Calculated residual current side H (I
EH
)
Stabilization currents side H (I
ESH
)
Maximum current I
L1H
-I
L2H
-I
L3H
(I
LmaxH
)
Maximum current (side H) between I
L1H
-I
L2H
-I
L3H
(I
LmaxH
)
Maximum current (side L) between I
L1L
-I
L2L
-I
L3L
(I
LmaxL
)
Minimum current (side H) between I
L1H
-I
L2H
-I
L3H
(I
LminH
)
Minimum current (side L) between I
L1L
-I
L2L
-I
L3L
(I
LminL
)
Average current (side H) between I
L1H
-I
L2H
-I
L3H
(I
LH
)
Average current (side L) between I
L1L
-I
L2L
-I
L3L
(I
LL
)
Demand phase
Phase fixed currents demand side H (I
L1FIXH
, I
L2FIXH
, I
L3FIXH
)
Phase fixed currents demand side L (I
L1FIXL
, I
L2FIXL
, I
L3FIXL
)
Phase rolling currents demand side H (I
L1ROLH
, I
L2ROLH
, I
L3ROLH
)
Phase rolling currents demand side L (I
L1ROLL
, I
L2ROLL
, I
L3ROLL
)
Phase peak currents demand side H (I
L1MAXH
, I
L2MAXH
, I
L3MAXH
)
Phase peak currents demand side L (I
L1MAXL
, I
L2MAXL
, I
L3MAXL
)
Phase minimum currents demand side H (I
L1MINH
, I
L2MINH
, I
L3MINH
)
Phase minimum currents demand side L (I
L1MINL
, I
L2MINL
, I
L3MINL
)
Protection
For each protection threshold, the following data are available:
For each protection threshold, the following data are available:
Start ON/OFF
Trip ON/OFF
Logic block (Block1) ON/OFF
Selective block (Block2) ON/OFF
Delayed inputs
The binary input states, acquired downstream the delay timers are available:
IN1 ON/OFF
IN2 ON/OFF
INx ON/OFF
Internal states
The state of the functions assigned to binary inputs are available:
Reset LEDs ON/OFF
Profile selection ON/OFF
Fault trigger ON/OFF
IE /IPh Block2 ON/OFF
IPh Block2 ON/OFF
IE Block2 ON/OFF
Block1 H-L and 87T ON/OFF
Block1 side H ON/OFF
Block1 side L ON/OFF
Block1 87T ON/OFF
Tcs1 side H ON/OFF
Tcs1 side L ON/OFF
Tcs2 side H ON/OFF
Tcs2 side L ON/OFF
External Trip ON/OFF
Reset partial counters ON/OFF
Reset dati CB monitoring ON/OFF
52a ON/OFF
52b ON/OFF
Open CB ON/OFF
Close CB ON/OFF
Remote trip ON/OFF
Reset on demand measures ON/OFF