EasyManuals Logo
Home>Trane>Heater>UniTrane

Trane UniTrane Installation, Operation And Maintenance Instructions

Trane UniTrane
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
UNT-SVX07B-EN 7
Each UniTrane fan-coil and Force-Flo
cabinet heater has a multiple charac-
ter model number unique to that par-
ticular unit. To determine a unit’s
specific options, reference the model
number on the unit nameplate on the
fan scroll. The unit nameplate also
identifies the serial number, sales
order number, and installation and
operating specifications.
Following is a complete description of
the fan-coil model number. Each digit
in the model number has a
corresponding code that identifies
specific unit options.
Note: Not all options are available on
all cabinet styles. Contact your
local Trane sales
representative for more
information.
Digits 1, 2 — Unit Type
FC = Fan-Coil
FF = Force-Flo
Digit 3 — Cabinet Type
A = Vertical Concealed
B = Vertical Cabinet
C = Horizontal Concealed
D = Horizontal Cabinet
E = Horizontal Recessed
H = Vertical Recessed
J = Vertical Cabinet Slope Top
K = Low Vertical Concealed
L = Low Vertical Cabinet
M = Inverted Vertical Cabinet
N = Inverted Vertical Recessed
Digit 4 — Development
Sequence “B
Digits 5, 6, 7 — Unit Size
Digit 8 — Unit Voltage
020 040 080
030 060 100
120
1 = 115/60/1 4 = 230/60/1
2 = 208/60/1 9 = 220–240/50/1
3 = 277/60/1
Digit 9 — Piping System/
Placement
A = No piping, RH, No Auxiliary Drain
Pan
B = No piping, LH, No Auxiliary Drain
Pan
C = No piping, RH, with Auxiliary
Drain Pan
D = No piping, LH, with Auxiliary
Drain Pan
E = No piping, RH, No Auxiliary Drain
Pan, Extended End Pocket
F = No piping, LH, No Auxiliary Drain
Pan, Extended End Pocket
G = No piping, RH, with Auxiliary
Drain Pan, Extended End Pocket
H = No piping, LH, with Auxiliary
Drain Pan, Extended End Pocket
J = With piping package, RH
K = With piping package, LH
L = With piping package, RH,
Extended End Pocket
M = With piping package, LH,
Extended End Pocket
Digits 10, 11 — Design Sequence
Digit 12 — Inlets
A = Front Toe Space
B = Front Bar Grille
C = Front Stamped Louver
D = Bottom Stamped Louver
E = Bottom Toe Space
F = Back Duct Collar
G= Back Open Return
H = Back Stamped Louver
Digit 13 — Fresh Air Damper
0=None
A = Manual, Bottom Opening
B = Manual, Back Opening
C = Manual, Top Opening
D = Auto, 2-Position, Bottom Opening
E = Auto, 2-Position, Back Opening
F = Auto, 2-Position, Top Opening
G = Auto, Economizer, Bottom
Opening
H = Auto, Economizer, Back Opening
J = Auto, Economizer, Top Opening
K = No Damper, Bottom Opening
L = No Damper, Back Opening
M = No Damper, Top Opening
Digit 14 — Outlets
A = Front Duct Collar
B = Front Bar Grille
C = Front Stamped Louver
D = Front Quad Grille
G = Top Quad Grille
H = Top Bar Grille
J = Top Duct Collar
Digit 15 — Color
0 = No Paint (Concealed Units Only)
1 = Deluxe Beige
2=Soft Dove
3 = Cameo White
4 = Driftwood Grey
5 = Stone Grey
6=Rose Mauve
Digit 16 — Tamperproof Locks/
Leveling Feet
0=None
B = Keylock Access Door
C = Keylock Panel and Access Door
D = Leveling Feet
F = Keylock Access Door with
Leveling Feet
G = Keylock Panel and Access Door
with Leveling Feet
Digit 17 — Motor
A = Free Discharge
B = High Static
Digit 18 — Coil
A = 2-Row Cooling/Heating
B = 3-Row Cooling/Heating
C = 4-Row Cooling/Heating
D = 2-Row Cooling/1-Row Heating
E = 2-Row Cooling/2-Row Heating
F = 3-Row Cooling/1-Row Heating
G = 2-Row Cooling Only
H = 3-Row Cooling Only
J = 4-Row Cooling Only
K = 2-Row Cooling/Heating with
Electric Heat
L = 3-Row Cooling/Heating with
Electric Heat
M = 4-Row Cooling/Heating with
Electric Heat
P = 2-Row Cooling/Heating with
1-Row Heating
Q = 2-Row Cooling/Heating with
2-Row Heating
R = 3-Row Cooling/Heating with
1-Row Heating
X = 2-Row Cooling Only, Electric Heat
Y = 3-Row Cooling Only, Electric Heat
Z = 4-Row Cooling Only, Electric Heat
Digit 19 — Drain Pan Material
3=Polymer Drain Pan
4 = Stainless Steel Main Drain Pan
Digit 20 — Coil Air Vent
A = Automatic Air Vent
M = Manual Air Vent
Model Number Descriptions

Table of Contents

Other manuals for Trane UniTrane

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane UniTrane and is the answer not in the manual?

Trane UniTrane Specifications

General IconGeneral
BrandTrane
ModelUniTrane
CategoryHeater
LanguageEnglish

Related product manuals