79
UTD4000 Four-channel
User Manual
Table 2- DMM Menu
37
Function Menu
Setup
Explanatory Note
Funtion
DMM functions on/off
ON/OFF
Mode
Voltage
Resistance
ON/OFF
Diode
DC current
Activate the voltage measurement function. Maximum measurement
value for DC voltage is 400V. Maximum measurement value for AC
voltage is 400V
Activate the resistance measurement function. Maximum measurement
value for resistance is 40M
Activate the on/off measurement function. When on/off measuring is
lower than 70 the beeper will sound
Activate the diode measurement function. Connect the positive pole to
the red , and the negative pole to the black test lead
Current range : 4mA, 40mA, 400mA, 4A
Ω
,
test lead
Win shift
Set the horizontal shift or vertical shift of the window with the
control knob
MULTIPURPOSE