DBW 2010 / 2016 5 Troubleshooting
505
5.4.2 Heater switches into fault mode repeatedly after approx. 30 s (20 s with 1563/1564 control
unit) when switched on
no
yes
Has thermal fuse F1
blown?
Has temperature lim-
iter been tripped?
Is the buzzing of
the (mechanical)
ignition spark
generator audi-
ble after approx.
20 s or 12 s?
Is voltage con-
nected to termi-
nals C8 and C5?
(1563/64 control
unit: terminals D8
and D5).
Check supply lines
from control unit.
Open circuit?
Is the same effect
produced with a new
ignition spark gener-
ator?
Ignition spark gener-
ator defective; re-
place.
Eliminate cause of
tripping, e.g. water
shortage.
Replace thermal fuse
or reset temperature
limiter.
Eliminate open cir-
cuit.
Insulator of ignition
electrodes defective.
Is the resistance/voltage of the flame monitor
without the effect of light > 100 kohms?
(with 1563/64 control unit: > 3.5 V)
Flame monitor defec-
tive; replace.
Control unit de-
fective; replace.
Does the solenoid
valve in the heater
open and - if due to
the tank located high-
er - does the existing
solenoid valve in the
intake and return po-
sition open?
Is a combustion
noise audible?
Does fuel spray
out of the atomis-
er nozzle?
Coil of magnetic head
defective.
no
Do the solenoid
valves have continui-
ty?
Solenoid valve defec-
tive; replace.
Is voltage connected
to the solenoid valve?
Check supply lines.
yes
Does the setting of
the ignition elec-
trodes match the
gauge?
Adjust ignition elec-
trodes using gauge.
Is fuel pumped by the
pump?
If there fuel in the
tank?
Refill.
Atomiser nozzle
clogged; replace.
Are all fuel lines
tightly connected?
Tighten, install new
seals.
Is the sealing surface
of the control piston
or the ventilation
hole soiled?
Remove fuel pump. Is
the driver on the
shaft OK?
Is the resistance/
voltage on the
flame monitor
with the effects
of light of 50 Lux
<1.56kohms?
(with 1563/64
control unit:
<3.5V)
Does the nozzle
atomise with a
limited spraying
angle?
Check intake and ex-
haust connection
piece for continuity;
clean if necessary.
Clean or replace. Intake line clogged.
Kerosene precipita-
tion or frozen water
inclusions.
Or: Ventilation open-
ing in tank closed.
Voltage at heater
is within limits of
undervoltage
protection of
control unit.
no
Is the viscosity below
20 cSt.?
Fuel quality does not
match mixing ratio in
accordance with op-
erating manual at
low temperatures.
Screen in intake con-
nection of fuel pump
soiled; clean.
yes
Flame monitor defec-
tive; replace.
yes
Charge battery. Atomiser nozzle
clogged; replace.
Replace fuel pump.
no
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com

Table of Contents

Other manuals for Webasto DBW 2010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Webasto DBW 2010 and is the answer not in the manual?

Webasto DBW 2010 Specifications

General IconGeneral
BrandWebasto
ModelDBW 2010
CategoryWater Heater
LanguageEnglish

Related product manuals