SVS-200 Installation, Operation and Maintenance
IMPORTANT INFORMATION SAVE THESE INSTRUCTIONS
20153-W-03-01 44 Webasto Charging Systems, Inc.
Table 6- 2 Warning Codes
Code
Warning Messages
Meaning
112
BMID Config
BMID data invalid, needs
configuration
116
Early Chrg Term
Charge terminated
unexpectedly
119
BMID TmpSnsor Fail
BMID temp sensor out of valid
range
124
Failed Backup Battery
Battery Backed Up Ram Has
Lost Data
125
Maximum Output Current Not
Set
Maximum Output Current Not
Set
126
Air System Failure
No Air Pressure has been
detected.
7 Technical Specifications
Model
number
INPUT
OUTPUT
Number
of
Phases
Freq
Hz
Voltage
AC
Current AMPS
Voltage
DC
Rating
kW
Curren
t
AMPS
SVS-300
3
50/60
440
46
16-130
30.0
320
12 to 48 cells
Flooded or Sealed battery
Up to 2500 Ah