上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
24 / 47
2. Click Pick Feature Pt to set the current point as feature point. The point will be
looked for during measuring magnification.
The point must be unique within the camera view.
See What Are the Requirements for the Selected Feature Points in Measuring
Magnification? for details.
3. Click Start to start to measure magnification.
After measuring the magnification finishes, do the following:
1. Click Start repeatedly to do several measurements.
2. Click Record to view the measurement results.
3. Remove the values changing greatly.
4.2.3. Measure the Offset between the Spindle and CCD
Without the offset between the spindle and CCD, the workpiece will deviates in the X
and Y directions.
To measure the offset between the spindle and CCD, do the following:
1. Turn the handwheel to make Z-axis slowly approach an useless area in the
workpiece.
2. Click Spindle on the port control area to enable the spindle.
3. Switch handwheel override to X10 and slowly deepen Z-axis to drill a hole.
4. Click Spindle again to disable the spindle.