上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
115 / 116
6.4 Specifications
Electric parameters
Working voltage & current (handheld device): 3V / 6 mA (two AA batteries)
Low voltage alarm (handheld device): < 2.2V
Transmitting power (handheld device): 14 dB
Receiver sensitivity: -90 dB
Wireless communication frequency: 433 MHz band
Delay: 32 ms
Other parameters
Lifespan of keys: 400–500 thousand times
Wireless communication distance: 40m in open spaces
Working temperature: -25°–70°
Anti-collision height: 1.5m
Receiver port: USB 2.0, with 1.5m USB dual-layer shield cable
USB communication distance: ≤5m
6.5 Precautions
Pay attention to the following:
Ensure that the wireless handwheel is connected properly before opening the
software.
Each handheld device has its matching USB receiver. Avoid mix use.
If the yellow indicator on the handwheel is on, the battery is about to run out. Use
new batteries in time.
Do not install the receiver inside cabinets to avoid affecting signal reception.
6.6 FAQs
If the following situations occur:
After pressing a handwheel button, the machine gives responses after a period of
delay.
After pressing a handwheel button, the machine has no response.
After pressing a handwheel button, it automatically pops back.
Check the working environment as follows:
Case one: The wireless handwheel is placed inside an indoor metal cabinet. No USB
extension cable is used. Communication distance is smaller than or equal to 2m.
Cause: The metal cabinet blocks transmission of wireless signal and causes
unstable communication.
Solution: Place the handwheel outside any metal cabinet, and use it in a barrier-
free environment.
Case two: The wireless handwheel is placed indoor and not inside any metal cabinet.
A USB extension cable of 2–3m long is used. Communication distance is 10m.
Cause: Use of extension cable can cause unstable communication. If the
interference is severe, it can cause exceptional USB communication and response
delay.
Solution: Do not use extension cable.