Page #108 background imageLoading...
Page #108 background image
Page – 108/139 AFFZP0BB – ACE3 – User Manual
Error
Code
Effect
Machine
status
When the
test is
done
Restart
procedure
Indication
CAN
OPEN
CODE
MDI
CODE
ZAPI
CODE
LED
BLINKS
stopped
DRV SHOR EV XX
MC is opened (the
command is released),
EB is applied,
Traction/Pump, valves
stopped
Start-up,
stand-by,
running
Valves or
Traction/Pump
Request
0xFFF9 21 234 21
PEV OPEN XX
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up,
stand-by,
running
MC is not closed,
EB is applied,
Traction/Pump,
valves stopped
0xFFDB 25 217 25
HW FAULT EB 01
HW FAULT EB 02
HW FAULT EB 03
MC is closed ,
EB is applied,
Traction/Pump
stopped
Start-up Key re-cycle 0xFFE5 34 229 34
EB. DRIV.SHRT.
MC remain closed, EB
is applied (the
command is released),
Traction/Pump, valves
stopped
Stand-by,
running
Valves or
Traction/Pump
Request
0x3222 40 254 40
EB. DRIV.OPEN
MC remain closed, EB
is applied (the
command is released),
Traction/Pump, valves
stopped
Running
Valves or
Traction/Pump
Request
0x3224 42 246 42
EB. COIL OPEN
MC remain closed, EB
is applied (the
command is released),
Traction/Pump, valves
stopped
Start-up,
Stand-by,
running
Valves or
Traction/Pump
Request
0xFFD8 43 216 43
HANDBRAKE
Traction/ Pump motor
is stopped
Start-up,
stand-by,
running
Traction/ Pump
request
0xFFDD 46 221 46
THROTTLE PROG.
MC remain closed, EB
is applied (the
command is released),
Traction stopped
Start-up,
Stand-by,
Valves or
Traction/Pump
Request
0xFFF3 48 243 48
LIFT + LOWER
Pump is stopped
Start-up,
stand-by,
Running
Pump request 0xFFBB 49 187 49
TILLER OPEN
LC opens
Start-up,
stand-by,
running
Valves or
Traction/Pump
Request
0x0000 51 228 51
WRONG ZERO
Valve, pump, traction
stopped,
LC opened, EB
applied
Start-up
Valves or Traction/
Pump request
0x3201 58 252 58
THERMIC SENS. KO
The maximum current
is reduced to half and
speed is reduced
Start-up,
stand-by,
running
0x4211 61 250 61
TH. PROTECTION
Traction controller
reduces the max
current linearly from
Imax (85°C) down to
0A (105°C)
Start-up,
stand-by,
running
0x4210 62 62 62