EasyManuals Logo
Home>Zapi>Inverter>ACE3

Zapi ACE3 User Manual

Zapi ACE3
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
AFFZP0BB – ACE3 – User Manual Page – 109/139
Error
Code
Effect
Machine
status
When the
test is
done
Restart
procedure
Indication
CAN
OPEN
CODE
MDI
CODE
ZAPI
CODE
LED
BLINKS
BRAKE RUN OUT
No effect, the warning
is only displayed
through the console
Continuous
Traction/Pump
Request
0xFFCC 63 204 63
Reload HM from MDI Start-up Key re-cycle 0x0000 94 0
94
MOTOR TEMPERAT.
The maximum current
is reduced to half and
speed is reduced
Start-up,
stand-by,
running
0x4110 65 65 65
MOTOR TEMP.
STOP
MC stays closed, EB is
applied,
Traction/Pump, valves
stopped
Continuous 0xFFB2 65 178 65
SENS MOT TEMP
KO
The maximum current
is reduced to half and
speed is reduced
Start-up,
stand-by,
running
0x4311 68 218 68
EPS RELAY OPEN
Traction/ Pump motor
is stopped
Start-up,
stand-by,
Running
Valves or Traction/
Pump request
0xFFCD 70 205 70
VACC NOT OK
Traction/ Pump motor
is stopped
Start-up,
stand-by,
running
Traction/ request 0xFF4E 78 78 78
INCORRECT START
Traction/ Pump motor
is stopped
Start-up,
stand-by
Traction request 0xFF4F 79 79 79
FORW + BACK Traction is stopped
Start-up,
stand-by,
running
Traction request 0xFF50 80 80 80
VACC OUT OF
RANGE
Traction/ Pump motor
is stopped
Start-up,
Stand-by,
Running
Traction/ Pump
request
0xFFE2 85 226 85
PEDAL WIRE KO
Traction is stopped
Start-up,
Stand-by,
Running
Traction request
0xFF56 86 86 86
WRONG SLAVE VER
MC opened, EB is
applied,
Traction/Pump, valves
stopped
Start-up Key re-cycle 0xFFC5 91 197 91
CURRENT GAIN
Controller works, but
with low maximum
current
Start-up,
stand-by
0x6302 92 236 92
PARAM TRANSFER
MC stays closed, EB is
applied,
Traction/Pump, valves
stopped
Continuous Key re-cycle 0xFFC7 93 199 93
Reload HM Start-up Key re-cycle 0x0000 94 0 94
STEER SENSOR KO
EB is applied,
traction/pump stopped
Continuous Key re-cycle 0xFFB3 95 179 95
M/S PAR CHK MISM
MC stays closed, EB is
applied,
Traction/Pump, valves
Start-up
Save again the
parameter and Key
re-cycle
0xFFC6 97 198 97