EasyManuals Logo
Home>3Com>Switch>SuperStack II

3Com SuperStack II User Manual

3Com SuperStack II
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
50 CHAPTER 4: CONNECTORS AND CABLES
V.35 DTE Cable
Pinouts
This cable connects the bridge/router to a V.35 DCE.
Figure 22 Flex-WAN and V.35 DTE Connectors
Table 14 V.35 DTE Cable Pinouts
Flex-WAN Connector V.35 DTE Connector
Signal Pin Direction Pin Signal Twisted Pair
*
*Unused twisted wires of a twisted pair should be connected to Shield Ground. In this cable this
is one wire of each of the twisted pairs 6 to 12.
SD/RD- 17 Q SD- 1
SD/RD+ 18 P SD-
SCTE/SCT- 19 W SCTE- 2
SCTE/SCT+ 20 U SCTE+
TxC/RxC- 23 AA SCT- 3
TxC/RxC+ 24 Y SCT+
RxC/TxCE- 25 X SCR- 4
RxC/TxCE+ 26 V SCR+
RxD/TxD- 27 T RD- 5
RxD/TxD+ 28 R RD+
DCD/LL 33 F RLSD 6
DSR/DTR 34 E DSR 7
CTS/RTS 35 D CTS 8
RTS/CTS 42 C RTS 9
DTR/DSR 43 H DTR 10
LL/DCD 44 K LT 11
Circuit Ground 45 - B Ground 12
Shield Ground 46 Cable Shield A Shield Ground -
Shorting Group 1 48
49
- - - -
Shorting Group 2 50
51
52
- - - -
Shorting Group 3 53
54
55
56
- - - -
60-pin Flex-WAN connector
V.35 male connector
To SuperStack II NETBuilder
To DCE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
60 59 58 57 56 55 54 53 52 51 50 49 48 47 46
B
F
L
R
V
Z
DD
JJ
NN
D
J
N
T
X
BB
FF
LL
C
H
M
S
W
A
EE
KK
A
E
K
P
U
Y
CC
HH
MM
HWBook Page 50 Friday, June 19, 1998 3:42 PM

Table of Contents

Other manuals for 3Com SuperStack II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3Com SuperStack II and is the answer not in the manual?

3Com SuperStack II Specifications

General IconGeneral
Brand3Com
ModelSuperStack II
CategorySwitch
LanguageEnglish

Related product manuals