CL settings
196
1SVC 440 795 M0100
Password setup
A password can be set up via the system menu in either RUN
or STOP mode. You cannot change to the system menu if a
password is already activated.
X Press DEL and ALT to call up the system menu.
X Select the menu option SECURITY… to enter the
password.
X Press the OK button and move to the PASSWORD…
menu.
X Press OK again to enter the Password entry mode.
If no password has been entered, the logic relay changes
directly to the password display and displays four XXXX
characters: No password present.
X Press OK, four zeros will appear
X Set the password using the cursor buttons:
úí select position in the password,
ÍÚ set a value between 0 to 9.
X Save the new password by pressing OK.
Use OK to exit the password display and proceed with ESC
and
Ú to the RANGE… menu.
The scope of the password has not yet been defined. The
password is now valid but not yet activated.
h
A password that has been entered in the logic relay is
transferred to the memory module together with the
circuit diagram, irrespective of whether it was activated or
not.
If this CL circuit diagram is loaded back from the memory
module, the password will also be transferred to the logic
relay and is activated immediately.
ENTER PASSW
âXXX
ENTER PASSW
0042