FSPS-21 (4000 m above
sea level
1)
)
FSPS-21 (at sea level,
0 m
1)
)
PROFIsafe
9,60E-041,55E-048,76E-05PFD
avg
T1 = 2 a)
1,64E-032,97E-048,76E-05PFD
avg
T1 = 5 a)
10,6383,99114155MTTF
D
(a)
00N/AHFT
334Cat.
99,75 %99,61 %99,00 %SFF (%)
99,49 %99,11 %99,00 %DC (%)
3AXD10000702254 rev B
1)
The safety data has been calculated based on the motor control profile as described in standard IEC
62380:2004, table 5.8.3. Use linear interpolation to calculate the values for intermediate altitudes.
Note:
For drive-specific STO safety data, see drive HW manual.
Relevant failure modes
Random hardware failures in FSPS-21 can prevent the activation of the STO output. The
probability of those and the coverage of the diagnostics is documented in the safety data
table above.
Related standards and directives
■ Related standards
NameStandard
Safety of machinery – General principles for design – Risk assessment and risk reductionEN ISO 12100:2010
Safety of machinery – Safety-related parts of control systems – Part 1: General principles
for design
EN ISO 13849-
1:2015
Safety of machinery – Safety-related parts of control systems – Part 2: ValidationEN ISO 13849-
2:2012
Safety of machinery – Electrical equipment of machines – Part 1: General requirementsEN 60204-1:2006 +
AC:2010
IEC 60204-1:2016
Generic standards - Immunity requirements for equipment intended to perform functions
in safety-related system (functional safety) in industrial locations
IEC 61000-6-7:2014
Functional safety of electrical/electronic/programmable electronic safety-related systemsIEC 61508 Parts 1-3,
Ed. 2.0:2010
Functional safety – Safety instrumented systems for the process industry sector – Part
1: Framework, definitions, system, hardware and application programming requirements
IEC 61511-1:2016
198 Technical data