DefaultDescriptionName/ValueNo.
N/ARead-only. Displays major and minor revision numbers
of the adapter module's firmware version in xxyy
format, where:
FBA A/B appl SW ver33
xx = major revision number
yy = minor revision number
Example: If the firmware version (<ma-
jor>.<minor>.<patch>.<build>) is 3.10.200.13 or
3.10.0.0, the value 310 is displayed.
See also parameter 32.
FSPS-21 configuration parameters – group B (group 2)
Note: The actual parameter group number depends on the drive type. Group B (group 2)
corresponds to:
• parameter group 53 in ACS380 and ACS580
• parameter group 53 in ACS880 if the adapter is installed as fieldbus adapter A or group
56 if the adapter is installed as fieldbus adapter B.
DefaultDescriptionName/ValueNo.
1 or 11
1)
Selects the resolution of control word (16 bit or 32 bit)
received by the drive.
FBA data out 1 (mas-
ter to drive)
01
Control word (16 bits)1 = CW 16bit
Control word (32 bits)11 = CW 32bit
0 or 2Selects data word 1 received by the drive over the
PROFINET network. The content is defined by a
decimal number in the range of 0 to 9999 as follows:
FBA data out 202
Not used0
Virtual address area of drive control1...99
Parameter area of the drive101...
9999
Not used0 = None
Control word (16 bits)1 = CW 16bit
Reference REF1 (16 bits)2 = Ref1 16bit
Reference REF2 (16 bits)3 = Ref2 16bit
Control word (32 bits)11 = CW 32bit
Reference REF1(32 bits)12 = Ref1 32bit
Reference REF2 (32 bits)13 = Ref2 32bit
Control word 2 (16 bits)21 = CW2 16bit
Parameter index with format xxyy, where101…9999
• xx is the parameter group number (1…99)
• yy is the parameter number index within that group
(01…99).
Path to parameter area selection.Other
54 PROFINET IO – Start-up