108 | RMC-100| 2105552MNAE
Figure 6-8: Enable port authentication from RBAC security editor
2. Click Save As to save changes to the security control file.
3. Type the password for the security control file into Current Password and click OK.
6.6.5.2 Enable authentication from the Entry mode
Enable one port at a time to enable RBCA authentication.
To use entry mode in Advanced or Expert view to configure or override communication port security:
1. Launch PCCU and click Entry. The navigation tree displays.
2. Click the communication port on the navigation tree.
3. Select Enabled or Enable by Security Switch from the Authentication drop-down list. (
Figure
6-9).
4. Click Send.
5. Repeat steps 1 through 4 for each of the communication ports.
Figure 6-9: Enable communication port authentication - Entry mode
6.6.6 Use default RBAC credentials
A login screen requests the user name and Password whenever PCCU connects to a flow computer
through an RBAC-enabled port.