7.3.3 Connect the AC input cable (3 phase)
Preliminary requirements
Torque screw driver AC input cable (3 phase, TN-
TT networks)
Procedure
1. Loosen the screws (A).
2. Insert the cable connector into the
terminal block (B).
3. Connect these wires:
1. Earthing wire (C)
2. Neutral wire (D)
3. L1 (E)
4. L2 (F)
5. L3 (G)
Refer to section
11.11
.
4. Tighten the screws (A) to the correct
torque. For the specification, refer to
section
11.16
.
7.3.4 Secure the cables
Preliminary requirements
Torque screw driver Strain relief for the cable
Procedure
1. Secure the cables (A) with the strain
relief (B).
2. Install the two screws (C) of the strain
relief.
B
E
D
F
G
C
A
A
B
C
Electrical installation