The second window of the DHW SYNOPTIC menu allows
the user to set daily time periods (maximum of two for each
day of the week) for DHW production; when the time periods
are activated, the heat pump will only produce hot water
during the time periods; this window displays the following
information:
- Day of the week (
1
): indicates which day of the week is
managed by the specifi ed time periods.
- First time period ON (
2
): indicates the time at which the
rst time period must start.
- First time period OFF (
3
): indicates the time at which the
rst time period must end.
- Second time period ON (
4
): indicates the time at which
the second time period must start.
- Second time period OFF (
5
): indicates the time at which
the second time period must end.
From this window it is possible to:
(1) Activate or deactivate the time periods for the production of
DHW:
to activate or deactivate the time periods for the chiller
currently selected, press the key
F
; pressing this key will
change the symbol highlighted above it according to one of
the following states:
- ( ) time periods DISABLED;
- ( ) time periods ENABLED.
If the system has the time periods enabled, the symbol (
O
N
O
FF
)
will appear on the main window.
(2) Select a day of the week at which to set the time
periods: pressing the key
E
will make it possible to scroll all
the days of the week; the day currently selected will appear
at the top part of the display (
1
).
(3) Set the time periods for the selected day: pressing the key
C
will allow you to enter modifi cation mode and the starting TIME
for the fi rst daily time period will be highlighted; at this point, the
procedure for setting the time periods will be:
a) press the keys
A
or
B
to increase or decrease the selected
value.
b) press the key
C
to confi rm and pass on to the subsequent data;
If you wish to set only one daily time period, you must set 00:00 for
the start (
4
) and for the end (
5
) of time period two.
(4) Disable the time periods for the selected day: to disable
the time periods on the selected day, ALL time period start
and end values must be set at 00:00.
(5) Copy the time periods of the day currently selected on
ALL the days of the week: to copy the same settings as the
day currently displayed for ALL days of the week, press the
key
D
.
(6) Go back to the previous window:
to go back to the previous window of this menu, press the
key
A
.
(7) Pass on to the next window:
to go to the next window of this menu, press the key
B
.
(8) Exit this window:
press the
G
key to return to the selection of the menus.
• Setting a daily time period for the production of domestic hot water:
!
ATTENTION: The setting of the time periods
must have coherent data; the logic to be
respected can be summarised with the
following relation:
2
<
3
<
4
<
5
If this relation is not respected, when all the
data has been entered a “DATA ERROR”
message will appear on the display,
disabling the entire daily time period.
If you would like to delete one or more time
periods, it is necessary to set the start and
end of that time period at 00:00.
A
B
G
C
D.H.W. timer
ESC
COPY
On
Off
10:00
12:10
15:30
18:00
D E
Sunday
D.H.W. timer
On
Off
10:00
12:10
15:30
18:00
Sunday
4
2 3
5
1
F

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AERMEC MULTI CONTROL and is the answer not in the manual?

AERMEC MULTI CONTROL Specifications

General IconGeneral
BrandAERMEC
ModelMULTI CONTROL
CategoryControl Panel
LanguageEnglish

Related product manuals