Appendix B
Parameters in the 1203-GK5 Module and
1336-GM5 Board
Appendix Objectives Appendix B provides information on the parameters in the 1203-GK5
module and 1336-GM5 board. In this appendix, you will read about
the following:
Factory-default settings.
Parameters in the 1203-GK5 module and 1336-GM5 board.
Factory Default Settings The factory-default settings of the 1203-GK5 module and 1336-GM5
board include the following:
16-bit Logic Command/Status enabled for polling.
16-bit Reference/Feedback enabled for polling.
If the scanner is put into program mode or the network faults, the
SCANport product is faulted.
A node address of 63.
DeviceNet data rate of 125 KBPS.
If you intend to change any of these settings, refer to Chapter 2,
Parameters in the 1203-GK5 Module and 1336-GM5 Board, for
detailed instructions.