6 Maintenance
6.1
Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustment, proceed
as follows:
•
Stop the compressor.
• Press the emergency stop button.
• Close the air outlet valve and open the manual condensate drain valves.
• For compressors equipped with electronic water drains, press the test
buttons on top of the electronic drains until the air system between the air
receiver and the outlet valve is fully depressurized.
• Switch off the voltage.
• Open and lock the isolating switch.
The operator must apply all relevant Safety precautions.
Warranty - Product Liability
Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts
is not covered by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Preventive maintenance schedule
The maintenance schedule is prior to the maintenance warnings displayed on the
controller. It is the responsibility of the owner to carry out the required maintenance at
the appropriate moment.
Period Running hours Operation
Daily 8 Check readings on display.
Daily 8 Check that condensate is discharged during loading.
Daily 8 Check oil level. Before starting, the level should be above the sight-
glass.
3-Monthly -- Check for air-, water- and oil leakages.
3-Monthly -- Check the contamination on the air- and oil-cooler surface, clean
externally if necessary.
3-Monthly -- Check the condition of the cooling fan assembly.
3-Monthly -- Check the condition of the air filters and cubicle filters, replace if
necessary.
See Oils -- Change oil.
Contact Atlas Copco to schedule the following maintenance intervals:
•
Yearly or 8000 hours
Instruction book
88 9829 3178 63