• 2 Yearly or 16000 hours
•
5 Yearly or 40000 hours
When operating in a dusty atmosphere, inspect the air filters more frequently.
Always use Atlas Copco filters.
The separator element must also be replaced when the pressure difference over the
element exceeds 0.8 bar (12 psi). Check the pressure drop when the compressor is
running with a stable working pressure.
Damaged flexibles must be replaced immediately.
Service agreements
Atlas Copco Customer Centres have a range of service agreements to suit your needs:
•
An Inspection Plan
• A Preventive Maintenance Plan
• A Warranty+ Plan
• A Total Responsibility Plan
Contact your Customer Centre to set up a tailor-made service agreement. It will ensure optimum
operational efficiency, minimize downtime and reduce the total life cycle costs.
Service plan
A number of service operations are grouped (called Level A, Level B, Level C...). Each level
stands for a number of service actions to be carried out at the time intervals programmed in the
Elektronikon regulator.
When a level is reached, a message will appear on the screen. After carrying out all service
actions, the interval timers must be reset using the “Reset” key in the “Service” menu. Consult
your Atlas Copco Service Centre.
6.2 Motors
Warning
• Stop the compressor and switch off the voltage. The operator must apply all
relevant Safety precautions.
Fan motors
The bearings of the fan motors are greased for life. The fan motor must be replaced after 40000
operating hours.
Bearing maintenance
The motor bearing is lubricated by oil injection. Re-greasing is not necessary.
Instruction book
9829 3178 63 89