42
K
Troubleshooting - What to do, if ...?
No comments
No comments
Use counter-
sink bit
No comments
No comments
See section F
See section F
No comments
See section F
Fault during Hinge insertion
Fault Cause of fault Eliminating fault Remarks
Hinges or fittings
cannot be inserted
at all, or can only
be inserted with
difficulties
Air pressure is not
sufficient
The insertion ram or
the swing arm is
hitting an object
The surface of the
panel is too hard
The drilling depth is
not deep enough
The diameter of the
drill bits is too small
The insertion ram is
off-set or installed
wrong
The panel moved on
the work table before
the insertion cycle
Shavings in holes
Insertion ram or
swing arm is
displaced or twisted
Adjust air pressure
to 6 bar (80-100 psi)
Remove object from
path of insertion ram
or swing arm
Check drilling
distance
Countersink holes
See point: Wrong
drilling depth
Check drill bits and
replace if necessary
Adjust insertion ram
Adjust hold-down
clamps so panel
does not move
during the operation
Check the shavings
air jet
drill deeper,
if possible
Adjust insertion ram
or swing arm
%$0,1,35(66)$,G1US $0