43
K
Troubleshooting - What to do, if ...?
Functional fault
Fault Cause of fault Eliminating fault Remarks
Motor does not run Machine not
connected to
electrical source
Machine not
connected to air
supply
Circuit breaker has
been thrown or fuse
has expired
Fuse under the
control panel has
expired
Switch not on
Swing arm is moved
down
Motor connected to
wrong voltage
Motor defective
Connect machine to
electrical source
Connect machine to
air supply
Switch on or replace
fuse
Repair by authorized
electrician or Blum
repair center
Main switch on
Pos.1
Move swing arm up
Check main voltage
and compare with
motor data. Replace
machine if voltage is
wrong
Replace motor by
authorized
electrician or return
to Blum repair
center
No comments
No comments
No comments
See electrical
schematic
See section E
See section F
See electrical
schematic
No comments