130 en | Appendix H Resetting to Factory Default Access Easy Controller 2.1
2018.11 | 1.0.6 | F.01U.122.796 Hardware Installation Manual Robert Bosch (SEA) Pte Ltd
25 Appendix H Resetting to Factory Default
On the first 4-Reader board of AEC2.1 system, JP2 is used to reset the panel to factory default
setting.
T12
T13
T14
T1
+
-
+
-
Fail
Tamper
Main
PWR
Earth
Shield
RS485
B A
RTS
GND
RS232
TX RX
+
-
+
-
IN
OUT
DC 15V
DC 15V
T11
12V
Gnd
DO-4
D1-4
LED4
BUZ4
12V
Gnd
DO-3
D1-3
LED3
BUZ3
T10
12V
Gnd
DO-2
D1-2
LED2
BUZ2
T9
12V
Gnd
DO-1
D1-1
LED1
BUZ1
T8
COM1
NC1
NO1
COM2
NC2
NO2
T2
LED1
LED2
COM3
NC3
NO3
COM4
NC4
NO4
T3
LED3
LED4
COM5
NC5
NO5
COM6
NC6
NO6
T4
LED5
LED6
COM7
NC7
NO7
COM8
NC8
NO8
T5
LED7
LED8
In5
Gnd
In6
Gnd
In7
Gnd
In8
Gnd
T7
In1
Gnd
In2
Gnd
In3
Gnd
In4
Gnd
T6
4-Reader Board
BOSCH
JP2
JP1
SW2
LED9
LED10
LED11
LED12
RUN
TX
RX
CARD READ
1 2
SW1
Set IP Address back to
factory default i.e.
192.168.0.41
Resetting all the configurations and
settings back to factory default. All
the data in the panel including card
numbers and advance IO settings
will be cleared. IP Address of the
panel will remain.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Access Easy Controller 2.1 and is the answer not in the manual?

Bosch Access Easy Controller 2.1 Specifications

General IconGeneral
BrandBosch
ModelAccess Easy Controller 2.1
CategoryController
LanguageEnglish

Related product manuals