Access Easy Controller 2.1 How to Install Reader and Field Devices | en 47
Robert Bosch (SEA) Pte Ltd Hardware Installation Manual 2018.11 | 1.0.6 | F.01U.122.796
10 How to Install Reader and Field Devices
This section summarizes the installation requirements for readers, door strikes and magnetic
locks, door contacts, request-to-exit devices, and miscellaneous alarm devices.
HID MiniProx Reader
HID ProxPro with Keypad Reader
HID ProxPro without Keypad Reader
HID ProxPoint Reader
Before mounting or wiring any hardware, be sure to read and understand the manufacturer's
documentation provided with each piece of equipment.
Also, be sure to use wire types and installation practices in full compliance with all applicable
codes, and in conformance with all requirements of local jurisdictional authorities.
1. Mount and wire readers in accordance with the manufacturer's instructions provided with
the readers.
When mounting a reader on a metal mullion or metal junction box, the screws
provided with the reader must be used. When mounting the reader on any other
surface, use appropriate fasteners.
The shield drain wire from the reader cable should be spliced to the shield
conductor of the reader cable coming from AEC2.1. The cables shield must be left
floating at the controller end. This configuration provides the best shielding from
external interference, and minimizes the likelihood of reader generated interference.
2. Mount and wire door strikes and/or electric locks.
Wire in accordance with manufacturer's instructions.
The door strike relays on the 4-Reader boards are designed to handle 1A@ 24 VDC
Resistive. This should satisfy most door strikes and magnetic locks. Should larger
current locks or strikes need to be controlled, then external interface relays must be
installed. External interface relay should also be used with all AC-powered door
strikes.
!
Warning!
VERY IMPORTANT: A suppression diode must be installed across the coil of all DC powered
door strikes and magnetic locks. The diode provides protection against the back-emf that is
generated when a strike/lock coil is de-energized. Refer to the door-wiring diagram for
additional details.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Access Easy Controller 2.1 and is the answer not in the manual?

Bosch Access Easy Controller 2.1 Specifications

General IconGeneral
BrandBosch
ModelAccess Easy Controller 2.1
CategoryController
LanguageEnglish

Related product manuals