LV-7292A/LV-7297A/LV-7392A/LV-7393A/LV-7398A/LV-8227A/LV-7292M/LV-7297M/LV-8227M
Expand Serial Command Functional Specifications
-13-
8.4.5 CF_IRIS Command (n/a LV-7292M/ LV-7297M/ LV-8227M)
Command “CF_IRIS_%1“[CR]
%1
“ON”-------------------Set Iris to On
“OFF” ”----------------Set Iris to Off
Details
Set Iris.
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]
8.4.6 CF_SHARP Command
Command “CF_SHARP_%1”[CR]
%1
“000~015” ---------------- Directly select Sharpness setting value
“UP” ------------------------ Current Sharpness setting value + 1
“DN” ------------------------ Current Sharpness setting value - 1
Details
Set Sharpness value of user control
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]
8.4.7 CF_GAMMA Command
Command “CF_GAMMA_%1”[CR]
%1
“000~015” ---------------- Directly set Gamma setting value
“UP” ------------------------ Current Gamma setting value + 1
“DN” ------------------------ Current Gamma setting value – 1
Details
Set Gamma value of user control
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]