LV-7292A/LV-7297A/LV-7392A/LV-7393A/LV-7398A/LV-8227A/LV-7292M/LV-7297M/LV-8227M
Expand Serial Command Functional Specifications

-37-
8.10.23 CF_PJPINCODE Command
Command “CF_PJPINCODE_%1”[CR]
%1 “0000” – “9999” ---------Set PJ PIN CODE directly
Details
Set PJ PIN CODE to release PJ LOCK.
PIN CODE cannot be changed by this command.
-When PJ LOCK is in operation
PIN CODE is correct ------------------------- Command is valid (Acceptable)
PIN CODE is incorrect ----------------------- Command is invalid(Error Code”102”)
PIN CODE is out of %1 range ------------- Command is invalid (Error Code “? “)
-When PJ LOCK is not in operation
PIN CODE is within %1 range ---------------- Command is valid (Acceptable)
PIN CODE is out of %1 range ---------------- Command is invalid (Error Code “? “)
This command is valid during a dialog “PJ PIN CODE” is displayed after Power On
and Count down.
Also when PJ LOCK setting is “On1”, it is necessary to transmit this command
every time lamp turns on.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]
8.10.24 CF_FANMODE Command
Command “CF_FANMODE_%1”[CR]
%1
“L1” ---------------------------- Set Fan Mode to L1
“L2” ---------------------------- Set Fan Mode to L2
Details
Switch Fan Mode
When L1 is selected, fan noise after POWER OFF is louder.
When L2 is selected, fan noise after POWER OFF becomes quiet, however, fan
rotates longer than L1.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]
8.10.25 CF_FANCONTROL Command
Command “CF_FANCONTROL_%1”[CR]
%1
“OFF” ---------------------------- Set Fan control to Off
“ON1” ---------------------------- Set Fan control to On1
“ON2” ---------------------------- Set Fan control to On2
Details
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]

Table of Contents

Other manuals for Canon LV-7392A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Canon LV-7392A and is the answer not in the manual?

Canon LV-7392A Specifications

General IconGeneral
BrandCanon
ModelLV-7392A
CategoryProjector
LanguageEnglish

Related product manuals