7-15
Cisco ASR 1001-X Router Hardware Installation Guide
OL-32376-02
Chapter 7 Removing and Replacing FRUs from the Cisco ASR 1001-X Router
Removing and Replacing a Cisco ASR 1001-X Router SPA
Number 2 Phillips or a 3/16-inch flat-blade screwdriver
SPA
Cables
Your own ESD-prevention equipment or the disposable grounding wrist strap included with all
upgrade kits, field-replaceable units (FRUs), and spares
Antistatic mat or surface, or static shielding bag
If you need additional equipment, contact a service representative for ordering information.
Electrostatic Discharge Prevention
Electrostatic discharge (ESD) damages equipment and impairs electrical circuitry. ESD occurs when
printed circuit boards are improperly handled and results in complete or intermittent failures.
Each SPA circuit board is mounted to a metal carrier and is sensitive to ESD damage. A SPA consists of
a printed circuit board that is fixed in a metal carrier. Electromagnetic interference (EMI) shielding,
connectors, and a handle are integral components of the carrier.
When the subslot is not in use, a SPA blank filler plate must fill the empty subslot to allow the router to
conform to EMI emission requirements and to allow proper airflow across the installed modules. If you
plan to install the SPA in the subslot that is not in use, you must first remove the SPA blank filler plate.
Figure 7-14 Handling the Cisco ASR 1001-X Router SPA
Although the metal carrier helps to protect the SPA from ESD, wear a preventive antistatic strap
whenever you handle the SPA. Ensure that the strap makes good skin contact and connect the strap’s clip
to an unpainted chassis surface to safely channel unwanted ESD voltages to ground.
If no wrist strap is available, ground yourself by touching the metal part of the chassis.
The following are the guidelines for preventing ESD damage:
1 Printed circuit board 2 Metal carrier
70006
Metal carrier
GND
Printed circuit board

Table of Contents

Other manuals for Cisco ASR 1001-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1001-X and is the answer not in the manual?

Cisco ASR 1001-X Specifications

General IconGeneral
Product colorGray
Rack capacity1U
Rack mountingYes
Networking standards-
Ethernet LAN (RJ-45) ports6
Installed SFP modules quantity2
Flash memory1024 MB
Internal memory8192 MB
Processor cores4
AC input voltage85 - 264 V
Power source typeAC
Power consumption (typical)250 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Security algorithmsAES
Weight and Dimensions IconWeight and Dimensions
Depth461.5 mm
Width439.42 mm
Height43.43 mm
Weight10590 g

Related product manuals