EasyManuals Logo
Home>Cisco>Network Router>ASR 903

Cisco ASR 903 Hardware Installation Guide

Cisco ASR 903
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
Connecting Cables to the Input 10Mhz or 1PPS Interface
Step 1
Connect one end of a mini-coax Y-cable to the GPS unit.
Step 2
Connect one end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the primary RSP of the Cisco ASR
903 Router.
Step 3
Connect the other end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the backup RSP of the Cisco
ASR 903 Router.
Connecting Cables to the Output 10Mhz or 1PPS Interface
Step 1
Connect one end of a mini-coax Y-cable to the Slave unit.
Step 2
Connect one end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the primary RSP of the Cisco ASR
903 Router.
Step 3
Connect the other end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the backup RSP of the Cisco
ASR 903 Router.
Connecting Cables to the ToD Interface
Step 1
Connect one end of a straight-through Ethernet cable to the GPS unit.
Step 2
Connect one end of the split-side Y-cable Ethernet to the ToD port on the primary RSP of the Cisco ASR 903 Router.
Step 3
Connect the other end of the split-side Y-cable Ethernet to the ToD port on the backup RSP of the Cisco ASR 903 Router.
For instructions on how to configure clocking, see the Cisco ASR 903 Router Software Configuration Guide.Note
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, connect
the ToD ports only to intra-building or unexposed wiring or cable. The intrabuilding cable must be shielded
and the shield must be grounded at both ends. The intra-building port(s) of the equipment or subassembly
must not be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are
designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE)
and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring.
Warning
For more information about GPS port pinouts, see Troubleshooting.Note
Cisco ASR 903 Aggregation Services Router Hardware Installation Guide
127
Installing the Cisco ASR 903 Router
Connecting Timing Cables

Table of Contents

Other manuals for Cisco ASR 903

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 903 and is the answer not in the manual?

Cisco ASR 903 Specifications

General IconGeneral
BrandCisco
ModelASR 903
CategoryNetwork Router
LanguageEnglish

Related product manuals