3-4
Cisco IE 3000 Switch Software Configuration Guide
OL-13018-03
Chapter 3 Configuring Cisco IE 3000 Switch Alarms
Configuring IE 3000 Switch Alarms
SNMP Traps
SNMP is an application-layer protocol that provides a message format for communication between
managers and agents. The SNMP system consists of an SNMP manager, an SNMP agent, and a
management information base (MIB).
The snmp-server enable traps command can be changed so that the user can send alarm traps to
an SNMP server. You can use alarm profiles to set environmental or port status alarm conditions to
send SNMP alarm traps. See the
“Enabling SNMP Traps” section on page 3-11 for more
information.
Syslog Messages
You can use alarm profiles to send system messages to a syslog server. See the “Configuring IE 3000
Switch Alarms” section on page 3-4 for more information.
Configuring IE 3000 Switch Alarms
This section describes how to configure the IE 3000 switch alarms:
Default IE 3000 Switch Alarm Configuration, page 3-4
Configuring the Power Supply Alarm, page 3-5
Configuring the Switch Temperature Alarms, page 3-6
Configuring the FCS Bit Error Rate Alarm, page 3-8
Configuring Alarm Profiles, page 3-9
Enabling SNMP Traps, page 3-11
Default IE 3000 Switch Alarm Configuration
Table 3-3 shows the default IE 3000 switch alarm configuration.
Ta b l e 3-3 Default IE 3000 Switch Alarm Configuration
Alarm Default Setting
Global Power Supply Alarm Enabled in switch single power mode. No alarm.
In dual-power supply mode, the default alarm notification is a system
message to the console.
Primary Temperature Alarm Enabled for switch temperature range of 203
o
F (95
o
C) maximum to –4°F
(–20
o
C) minimum.
The primary switch temperature alarm is associated with the major relay.
Secondary Temperature Alarm Disabled.
Port Link Fault Alarm Disabled on all interfaces.
Port not Forwarding Alarm Disabled on all interfaces.
Port not Operating Alarm Enabled on all interfaces.
FCS Bit Error Rate Alarm Disabled on all interfaces.

Table of Contents

Other manuals for Cisco IE-3000-8TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-3000-8TC and is the answer not in the manual?

Cisco IE-3000-8TC Specifications

General IconGeneral
BrandCisco
ModelIE-3000-8TC
CategorySwitch
LanguageEnglish

Related product manuals