3-12
Cisco IE 3000 Switch Software Configuration Guide
OL-13018-03
Chapter 3 Configuring Cisco IE 3000 Switch Alarms
Displaying IE 3000 Switch Alarms Status
Beginning in privileged EXEC mode, follow these steps to enable the switch to send alarm traps:
Displaying IE 3000 Switch Alarms Status
To display the global and port alarm status, use one or more of the privileged EXEC commands in
Table 3-5:
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
snmp-server enable traps alarms Enable the switch to send SNMP traps.
Step 3
end Return to privileged EXEC mode.
Step 4
show alarm settings Verify the configuration.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Ta b l e 3-5 Commands for Displaying Global and Port Alarm Status
Command Purpose
show alarm description port Displays an alarm number and its text description.
show alarm profile [name] Displays all alarm profiles in the system or a specified profile.
show alarm settings Displays all global alarm settings on the switch.
show env {all | power | temperature} Displays the status of environmental facilities on the switch.
show facility-alarm status [critical | info |
major | minor]
Displays generated alarms on the switch.