Table 10: 1050 W AC Specifications
SpecificationDescription
Nominal range: 100–120 VAC, 200–240 VAC
(Range: 90–132 VAC, 180–264 VAC)
AC Input Voltage
Nominal range: 50 to 60Hz
(Range: 47–63 Hz)
AC Input Frequency
12.5 A at 100 VAC
6.0 A at 208 VAC
Maximum AC Input current
1250 VA at 100 VACMaximum input volt-amperes
15 A (sub-cycle duration)Maximum inrush current
12 ms at 1050 WMaximum hold-up time
800 W at 100–120 VAC
1050 W at 200–240 VAC
Maximum output power per PSU
12 VDCPower supply output voltage
12 VDCPower supply standby voltage
Climate Savers Platinum Efficiency (80Plus Platinum certified)Efficiency rating
RSP2Form factor
IEC320 C14Input connector
Power Cord Specifications
Each power supply in the server has a power cord. Standard power cords or jumper power cords are available
for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional
alternative to the standard power cords.
Only the approved power cords or jumper power cords listed below are supported.
Note
Table 11: Supported Power Cords
Length (Meters)Length (Feet)Description
3.511.7CAB-48DC-40A-8AWG
DC power cord, -48 VDC, 40 A, 8 AWG
Three-socket Mini-Fit connector to three-wire
Cisco Application Services Engine Hardware Installation Guide
87
Server Specifications
Power Cord Specifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SE-CL-L3 and is the answer not in the manual?

Cisco SE-CL-L3 Specifications

General IconGeneral
BrandCisco
ModelSE-CL-L3
CategoryServer
LanguageEnglish

Related product manuals