xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
234
Example
To display BPDU protection information for the entire switch:
DGS-3620-28SC:admin#show bpdu_protection
Command: show bpdu_protection
BPDU Protection Global Settings
---------------------------------------
BPDU Protection Status : Disabled
BPDU Protection Recover Time : 60 seconds
BPDU Protection Trap State : None
BPDU Protection Log State : Both
DGS-3620-28SC:admin#
To display BPDU protection status for ports 1 to 3:
DGS-3620-28SC:admin#show bpdu_protection ports 1-3
Command: show bpdu_protection ports 1-3
Port State Mode Status
----- ----------- ---------- -----------
1 Disabled Shutdown Normal
2 Disabled Shutdown Normal
3 Disabled Shutdown Normal
DGS-3620-28SC:admin#