87
System display
Status Icon
Status information under the
icon
Motor running Symbol of pump turning VSHHGLQWKUHH¿JXUHV
Motor stopped Symbol of static pump SB
Device faulty Symbol of static pump F
,IWKHGHYLFHLVFRQ¿JXUHGDVUHVHUYHWKHWRSSDUWRIWKHLFRQGHSLFWLQJWKH
motor is coloured, the display remains similar to Table 9 with the excep-
tion that, if the motor is stopped, it shows F instead of SB.
To leave for space for displaying the system the name of the
parameter SM does not appear, but just the word “system”
centrally placed under the name of the menu.
7.1.9 - VE: Version display
Hardware and software version with which the appliance is equipped.
7.1.10 - PI: Power histogram
A histogram of the power delivered is displayed on 5 vertical bars. The
histogram indicates how long the pump has been on at a given power
level. On the horizontal axis are the bars at the various power levels; on
WKHYHUWLFDOD[LVWKHWLPHIRUZKLFKWKHSXPSKDVEHHQRQDWWKHVSHFL¿F
SRZHUOHYHORIWKHWLPHZLWKUHVSHFWWRWKHWRWDO.
Table 12: View of the multi-pump system
Figura 18: Power histogram display
87
7.1.1 - Status:
Displays the pump status.
7.1.2 - RS: Rotation speed display
Motor rotation speed in rpm.
7.1.3 - VP: Pressure display
Plant pressure measured in [bar] or [psi] depending on the measuring
system used.
7.1.4 - VF: Flow display
'LVSOD\VWKHLQVWDQWDQHRXVÀRZLQ>OLWUHVPLQ@RU>JDOPLQ@GHSHQGLQJRQ
the set measuring system.
7.1.5 - PO: Absorbed power display
Power absorbed by the electropump in [kW].
$ÀDVKLQJURXQGV\PEROPD\DSSHDUXQGHUWKHV\PERORIWKHPHDVXUHG
power PO. This symbol indicates the pre-alarm for exceeding the allowed
maximum power
7.1.6 - C1: Phase current display
Motor phase current in [A].
$ÀDVKLQJURXQGV\PEROPD\DSSHDUXQGHUWKHV\PERORIWKHSKDVHFXU-
rent C1. This symbol indicates the pre-alarm for exceeding the allowed
PD[LPXPFXUUHQW,ILWÀDVKHVDWUHJXODULQWHUYDOVLWPHDQVWKDWWKHPRWRU
overload protection is about to trip and it will very probably go into protec-
tion status
7.1.7 - Operating hours and number of starts
Indicates on three lines the hours that the device has been switched on,
the pump working hours and the number of starts of the motor.
7.1.8 - Multi-pump system
Displays the system status when in the presence of a multi-pump instal-
lation. If communication is not present, an icon depicting communication
absent or interrupted is displayed. If there are several devices connected
to one another, an icon is shown for each of them. The icon has the sym-
bol of a pump under which are characters indicating the pump status.
Depending on the operating status it will display as in Table 9.
ENGLISH
GB