Parameter Function
Record Delay
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Alarm out Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding
alarm device when an alarm occurs.
Latch System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.
Show message System can pop up a message to alarm you in the local
host screen if you enabled this function.
Buzzer Check the box here to enable this function. The buzzer
beeps when an alarm occurs.
Alarm upload System can upload the alarm signal to the centre
(Including alarm centre).
Send Email If you enabled this function, System can send out an email
to alert you when an alarm occurs.
Tour You need to click setup button to select tour channel.
System begins 1-wiindow or multiple-window tour display
among the channel(s) you set to record when an alarm
occurs. See Figure 4-54.
PTZ Activation Here you can set PTZ movement when an alarm occurs.
Such as go to preset X. See Figure 4-64.
Snapshot Click setup button to select snapshot channel. See Figure
4-55.
4.8.3.4.2 Net Alarm
From main menu->Setup->Event->Alarm->Net alarm, the network alarm interface is shown as in Figure
4-65.
Network alarm refers to the alarm signal from the network. System does not anti-dither and sensor type
setup. For setup information, please refer to chapter 4.8.3.4.1.
180