1-2
VLT is a registered Danfoss trademark
Status Display
The status line of the display (line 4) reports inputs commanding
drive operations.
The VLT 5000 series drives have a slightly different status display
format than the VLT 4000/6000/8000 series drives.
12 3
1. For the VLT 4000/6000/8000, the first status
display indicates where the start command
comes from, automatic or hand start. In auto
start, the drive looks for a remote start signal. In
hand start, the drive receives a local input
through the [HAND START] key.
2. The second status display indicates where the
speed command comes from, remote or local.
Local responds to the [+] and [-] keys on the
keypad. Remote looks for an external reference
signal.
3. The third display shows the operational status of
the drive: running, stopped, stand by, ramping,
and so on.
For the VLT 5000 series, the status display on line 4 is not
segmented. It shows the operational status of the drive with
the local or remote indication as part of the display title.
Tables 1-1 and 1-2 list the displays shown in the status line
and define their meaning. Because the VLT 5000 series and
VLT 4000/6000/8000 series have different display status
indications, the definitions appear in separate tables.
Familiarity with the status display provides information regarding
the operational mode of the drive. The status line displays are
not programmable.
Factory Default Display Settings
Any of the values shown by scrolling through the display in line
2 are also available to display in the three meter displays on
line 1. See the drive instruction manual for procedures on
programming drive parameters.
Factory default values and associated parameters for VLT 5000
series drives are shown below.
Line 1 displays:
010 Reference (%)
011 Motor current (A)
012 Power (kW)
Factory default values and associated parameters for VLT 4000
/6000/8000 series drives are shown below.
Line 1 displays:
008 Reference (%)
009 Motor current (A)
010 Power (hp)
Line 2 display:
009 Frequency (Hz)
Line 2 display:
007 Frequency (Hz)
SETUP
1
FREQUENCY
AUTO REM. RUNNING
60.0Hz
HAND
OFF
STOP
RAMPING
JOGGING
.
.
.
.
STAND BY
LOCAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000-P and is the answer not in the manual?

Danfoss VLT 5000-P Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000-P
CategoryDC Drives
LanguageEnglish

Related product manuals