Table 1-2. VLT 4000/6000/8000 Series Status Definitions
DISPLAY DESCRIPTION
CONTROL POINT
AUTO Drive in Auto mode, which means that Run/Stop control is carried out
remotely via input control terminals and/or serial communication.
HAND Drive in Hand mode, which means that Run/Stop control is carried out
via keys on the keypad.
OFF OFF/STOP activated either by means of keypad or by digital input
terminals.
REFERENCE LOCATION
REM. REMOTE selected, which means reference is set via input control
terminals or serial communication.
LOCAL LOCAL selected, which means reference is set with [+] and [-] keys on
keypad.
DRIVE STATUS
AMA RUN
Automatic motor adaptation enabled in parameter 107,
Automatic Motor
Adaptation, AMA
and drive performing adaptation function.
AMA STOP Automatic motor adaptation completed. Drive is now ready for
operation after
Reset
enabled. Motor may start after drive reset.
AUTO RAMP Parameter 208,
Automatic Ramp
, enabled. Drive is attempting to avoid
a trip from overvoltage by extending decel ramp time.
CTR.READY This status only active when a Profibus option card is installed.
DC STOP DC brake enabled in parameters 114 through 116.
FRZ.OUT Drive output frequency frozen at fixed rate from input command.
FRZ.REQ Start command to run at current frequency given but motor will not start
until a
Run Permission
signal is received via a digital input.
JOG Jog enabled via digital input or serial communication. Drive is running
at a fixed frequency set in parameter 209,
Jog Frequency.
JOG REQ. Start command to run at jog frequency given but motor will not start
until a
Run Permission
signal is received via a digital input.
NOT READY Drive not ready for operation because of a trip or because OFF1, OFF2
or OFF3 is a logic ‘0.
RAMPING Motor speed and drive output frequency is changing.
RUN REQ. Start command given but motor will not start until a
Run Permission
signal is received via digital input.
RUNNING Motor running and speed corresponds to reference.
SLEEP Parameter 403,
Sleep Mode Timer,
enabled. Motor stopped in sleep
mode. It can restart automatically.
SLEEP.BST
Sleep boost function in parameter 406,
Boost Setpoint,
enabled. Drive
is ramping up to boost setpoint.
STANDBY Drive able to start motor when a start command is received.
START Reversing and start
on terminal 19, parameter 303,
Digital Inputs
, and
Start
on terminal 18, parameter 302,
Digital Inputs,
are both enabled.
Motor will remain stopped until either signal becomes logic ‘0.’
START DEL
Start delay time programmed in parameter 111,
Start Delay
. When
delay time expires, drive will start and ramp up to reference frequency.
START IN. This status only displayed if parameter 599,
Profidrive
[1] selected and
OFF2 or OFF3 is a logic ‘0.’
STOP Motor stopped via a stop signal from serial communication.
UN.READY Unit ready for operation but digital input terminal 27 is logic ‘0’ and/or a
Coasting Command
received via serial communication.
XXXX Control microprocessor stopped for unknown cause and drive not
operating. Cause may be noise on the power line, motor leads or
control wires.
Table 1-2 defines the status line display shown in VLT 4000/
6000/8000 series drives.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000-P and is the answer not in the manual?

Danfoss VLT 5000-P Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000-P
CategoryDC Drives
LanguageEnglish

Related product manuals