4 Mechanical Installation
4.1 Receiving and Unpacking the Unit
4.1.1 Items Supplied
Make sure that the items supplied and the
information on the labels correspond to the
order.
- Top-level drive system. This label is
found on the control shelf, lower right
side of the LCP. See Illustration 3.2.
- Drive module. This label is found inside
the drive module enclosure, on the right
side panel. See Illustration 3.1.
Visually check the packaging and the VLT
®
Parallel Drive Modules components for damage
caused by inappropriate handling during
shipment. File any claim for damage with the
carrier. Retain damaged parts, in case
clarication
is needed.
130BE710.12
OUT: 3x0-Vin 0-590Hz 1260/1160 A
IN: 3x380-500V 50/60Hz 1227/1129 A
710 kW / 1000 HP, High Overload
OUT: 3x0-Vin 0-590Hz 1460/1380 A
IN: 3x380-500V 50/60Hz 1422/1344 A
800 kW / 1200 HP, Normal Overload
VLT
T/C: FC-302N710T5E00P2BGC7XXSXXXXAXBXCXXXXDX
P/N: 134X4109 S/N:
R
AutomationDrive
www.danfoss.com
1
2
3
4
5
6
ASSEMBLED IN USA
CAUTION - ATTENTION:
Stored charge, wait 20 min.
Charge residuelle, attendez 20
See manual for special condition / prefuses
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
`
`
Tamb. 45
˚
C/113
˚
F at Full Output Current
CHASSIS (OPEN TYPE) / IP00
SCCR 100 kA at UL Voltage range 380-500 V
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
Max. Tamb. 55
˚
C/131
˚
F w/ Output Current Derating
123456H123
1 Type code
2 Code number
3 Power rating
4 Input voltage, frequency, and current
5 Output voltage, frequency, and current
6 Discharge time
Illustration 4.1 Top-level Drive System Label (Example)
130BE711.14
Intended use - The Individual Base Drive
Modules are intended for use in Parallel Drive
Module system only. Specic electrical
ratings are not applicable. Name plate of
Parallel Drive Module system should
be referred for actual drive ratings.
VLT
ASSEMBLED IN USA
T/C: FC-BDMN250T5E00H2SXC7XXSXXXXAXBXCXXXXDX
P/N: 178N0025 S/N: 123456H123
CAUTION - ATTENTION:
Stored charge, wait 20 min.
Charge residuelle, attendez 20
See manual for special condition / prefuses
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
R
AutomationDrive
www.danfoss.com
`
`
CHASSIS (OPEN TYPE) / IP00
SCCR 100 kA at UL Voltage range 380-500 V
Listed 36U0 E70524 IND. CONT. EQ.
1
2
3
4
5
UL Voltage range 380-500 V
1 Type code
2 Code number
3 Intended use disclaimer
4 Discharge time
5 Serial number
Illustration 4.2 Drive Module Label (Example)
NOTICE
LOSS OF WARRANTY
Removing the labels from the VLT
®
Parallel Drive
Modules can result in loss of warranty.
Mechanical Installation Installation Guide
MG37K302 Danfoss A/S © 08/2017 All rights reserved. 11
4 4

Table of Contents

Other manuals for Danfoss vlt FC 102