6.4.3 Comm. and Options 8-**
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion index
Type
8-0* General Settings
8-01 Control site
[0] Digital and
ctrl.word All set-ups TRUE - Uint8
8-02 Control word source null All set-ups TRUE - Uint8
8-03 Control word timeout time 1.0 s 1 set-up TRUE -1 Uint32
8-04 Control word timeout function [0] Off 1 set-up TRUE - Uint8
8-05 End-of-timeout function [1] Resume set-up 1 set-up TRUE - Uint8
8-06 Reset control word timeout [0] Do not reset All set-ups TRUE - Uint8
8-3* FC Port Settings
8-30 Protocol [1] FC MC 1 set-up TRUE - Uint8
8-31 Address 2 N/A 1 set-up TRUE 0 Uint8
8-32 FC port baud rate [2] 9600 Baud 1 set-up TRUE - Uint8
8-33 Parity/stop bits
[0] Even parity, [1]
Stop bit All set-ups TRUE Uint8
8-35 Minimum response delay 10 ms All set-ups TRUE -3 Uint16
8-36 Max response delay 5000 ms 1 set-up TRUE -3 Uint16
8-37 Max inter-char delay 25 ms 1 set-up TRUE -3 Uint16
8-4* FC MC Protocol Set
8-42 PCD write configuration [1685] FC port CTW 1 All set-ups TRUE Uint16
8-43 PCD read configuration [1603] Status word All set-ups TRUE Uint16
8-5* Digital/Bus
8-53 Start select [3] Logic OR All set-ups TRUE - Uint8
8-55 Set-up select [3] Logic OR All set-ups TRUE - Uint8
6.4.4 Special Functions 14-**
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion index
Type
14-2* Trip Reset
14-20 Reset mode [0] Manual reset All set-ups TRUE - Uint8
14-21 Automatic restart time 10 s All set-ups TRUE 0 Uint16
14-22 Operation mode [0] Normal operation All set-ups TRUE - Uint8
14-23 Typecode setting null 2 set-ups FALSE - Uint8
14-28 Production settings [0] No action All set-ups TRUE - Uint8
14-29 Service code 0 N/A All set-ups TRUE 0 Int32
14-5* Environment
14-50 RFI filter [1] On 1 set-up FALSE - Uint8
14-53 Fan monitor [1] Warning All set-ups TRUE - Uint8
14-54 Bus partner 1 N/A 2 set-ups TRUE 0 Uint16
Programming Operating Instructions
108 Danfoss A/S © Rev. 2014-07-29 All rights reserved. MG37A202
66

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 302 and is the answer not in the manual?

Danfoss VLT FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 302
CategoryController
LanguageEnglish

Related product manuals