EasyManuals Logo
Home>Danfoss>Controller>VLT FC 302

Danfoss VLT FC 302 User Manual

Danfoss VLT FC 302
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
5.1.12 PC Software Tools
PC-based Configuration Tool MCT 10 Set-up Software
The Low Harmonic Drive is equipped with 2 serial
communication ports. Danfoss provides a PC tool for
communication between PC and frequency converter, MCT
10 Set-up Software. Check chapter 2.4 Additional Resources
for detailed information on this tool.
MCT 10 set-up software
MCT 10 is an interactive tool for setting parameters in
Danfoss frequency converters. The software can be
downloaded from the Danfoss Internet site
www.danfoss.com/BusinessAreas/DrivesSolutions/Software-
download/DDPC+Software+Program.htm.
The MCT 10 set-up software is useful for:
Planning a communication network off-line. MCT
10 contains a complete frequency converter
database
Commissioning frequency converters online
Saving settings for all frequency converters
Replacing a frequency converter in a network
Simple and accurate documentation of frequency
converter settings after commissioning.
Expanding an existing network
Future developed frequency converters are
supported
MCT 10 set-up software supports Profibus DP-V1 via a
Master class 2 connection. It enables online read/write
parameters in a frequency converter via the Profibus
network, eliminating the need for an extra communication
network.
Save frequency converter settings
1. Connect a PC to the unit via USB com port.
CAUTION
Use a PC, which is isolated from the mains, with the USB
port. Failure to do so can damage equipment.
2. Open MCT 10 Set-up Software
3. Select “Read from drive”
4. Select “Save as”
All parameters are now stored in the PC.
Load frequency converter settings
1. Connect a PC to the frequency converter via USB
com port
2. Open MCT 10 Set-up software
3. Select “Open” to show stored files
4. Open the appropriate file
5. Select “Write to drive”
All parameter settings are now transferred to the
frequency converter.
User Interface Operating Instructions
48 Danfoss A/S © Rev. 2014-07-29 All rights reserved. MG37A202
55

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 302 and is the answer not in the manual?

Danfoss VLT FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 302
CategoryController
LanguageEnglish

Related product manuals