6.4.7 AF Settings 300-**
NOTICE
Except for 300-10 Active Filter Nominal Voltage, it is not recommended to change the settings in this parameter group
for the Low Harmonic Drive
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion
index
Type
300-0* General Settings
300-00 Harmonic cancellation mode [0] Overall All set-ups TRUE - Uint8
300-01 Compensation priority [0] Harmonics All set-ups TRUE - Uint8
300-08 Lagging reactive current [0] Disabled All set-ups FALSE Uint8
300-1* Network Settings
300-10 Active filter nominal voltage ExpressionLimit 2 set-ups FALSE 0 Uint32
300-2* CT Settings
300-20 CT primary rating ExpressionLimit 2 set-ups FALSE 0 Uint32
300-24 CT Sequence [0] L1, L2, L3 2 set-ups FALSE - Uint8
300-25 CT Polarity [0] Normal 2 set-ups FALSE - Uint8
300-26 CT Placement [1] Load Current 2 set-ups FALSE - Uint8
300-27 Number of CTs per phase 1 All set-ups FALSE Uint8
300-29 Start auto CT detection [0] Off All set-ups FALSE - Uint8
300-3* Compensation
300-30 Compensation points 0.0 A All set-ups TRUE -1 Uint32
300-35 Cosphi reference 0.500 N/A All set-ups TRUE -3 Uint16
300-4* Paralleling
300-40 Master follower selection [2] Not Paralleled 2 set-ups FALSE - Uint8
300-41 Follower ID 1 N/A 2 set-ups FALSE 0 Uint32
300-42 Num. of follower AFs 1 N/A 2 set-ups FALSE 0 Uint32
300-5* Sleep Mode
300-50 Enable sleep mode null 2 set-ups TRUE - Uint8
300-51 Sleep mode trig source [0] Mains current All set-ups TRUE - Uint8
300-52 Sleep mode wake up trigger ExpressionLimit All set-ups TRUE 0 Uint32
300-53 Sleep mode sleep trigger 80 % All set-ups TRUE 0 Uint32
6.4.8 AF Readouts 301-**
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion
index
Type
301-0* Output Currents
301-00 Output current [A] 0.00 A All set-ups TRUE -2 Int32
301-01 Output current [%] 0.0 % All set-ups TRUE -1 Int32
301-1* Unit Performance
301-10 THD of current [%] 0.0 % All set-ups TRUE -1 Uint16
301-12 Power factor 0.00 N/A All set-ups TRUE -2 Uint16
301-13 Cosphi 0.00 N/A All set-ups TRUE -2 Int16
301-14 Leftover currents 0.0 A All set-ups TRUE -1 Uint32
301-2* Mains Status
301-20 Mains current [A] 0 A All set-ups TRUE 0 Int32
301-21 Mains frequency 0 Hz All set-ups TRUE 0 Uint8
301-22 Fund. mains current [A] 0 A All set-ups TRUE 0 Int32
Programming Operating Instructions
MG37A202 Danfoss A/S © Rev. 2014-07-29 All rights reserved. 111
6 6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 302 and is the answer not in the manual?

Danfoss VLT FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 302
CategoryController
LanguageEnglish

Related product manuals