WARNING 202, Fire Mode Limits Exceeded
Fire mode has suppressed 1 or more warranty-voiding
alarms.
ALARM 250, New Spare Part
The power or switch mode supply has been exchanged.
ALARM 251, New Type Code
The frequency converter has a new type code.
4.6 List of LCP Errors
LCP errors are not warnings or alarms. They do not aect the operation of the frequency converter. Illustration 4.1 shows an
LCP error on the LCP.
Error 84
LCP comm. lost
Setup 1
130BE106.10
Illustration 4.1 LCP Error Example
LCP error code Error message Description
Err 84 LCP comm. Lost Communication between the LCP and the frequency converter is lost.
Err 85 Key disabled
The LCP key is disabled. One of the LCP keys has been disabled in parameter group
0-4* LCP Keypad.
Err 86 LCP copy failed
Data copy failure. This error occurs when data is copied from frequency converter to
LCP, or from LCP to frequency converter (parameter 0-50 LCP Copy).
Err 88 Data not compatible
LCP data incompatible. This error occurs when data is being copied from LCP to
frequency converter (parameter 0-50 LCP Copy). The typical reason is that data is
moved between frequency converter and LCP that have major software dierences.
Err 89 Read only
Parameter read only. An operation is issued via LCP to write a value to a parameter
that is read-only.
Err 90 Database busy The parameter database of the frequency converter is busy.
Err 91 Parameter invalid The parameter value that is input via the LCP is invalid.
Err 92 Exceeds limits The parameter value that is input via the LCP exceeds limits.
Err 93 Motor is running
The LCP copy operation cannot be performed when the frequency converter is
running.
Err 95 Not while running The parameter cannot be changed while the frequency converter is running.
Err 96 Password rejected The password that is input via the LCP is incorrect.
Table 4.6 LCP Error List
Troubleshooting
VLT
®
HVAC Basic Drive FC 101
104 Danfoss A/S © 04/2018 All rights reserved. MG18B502
44

Table of Contents

Other manuals for Danfoss VLT HVAC Basic Drive FC 101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT HVAC Basic Drive FC 101 and is the answer not in the manual?

Danfoss VLT HVAC Basic Drive FC 101 Specifications

General IconGeneral
BrandDanfoss
ModelVLT HVAC Basic Drive FC 101
CategoryDC Drives
LanguageEnglish

Related product manuals