EasyManuals Logo
Home>Datamax>Printer>A-4310

Datamax A-4310 User Manual

Default Icon
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
Label Formatting Command Functions
Class Series Programmer’s Manual 119
r Recall Stored Label Format
This command is used to retrieve label formats stored on a memory module.
Syntax:
rnn...n
Where:
nn…n
- Is a label name, up to 16 characters in length.
The samples below explain different ways to recall and print a label format. (To view a memory
module’s directory of label formats use the <STX>W command.)
String Sent: Printer Interpretation:
Sample 1:
<STX>L<CR>
rTEST<CR>
Q0002<CR>
E<CR>
Begin label format
Retrieve format named TEST
Quantity requested = 2
Terminate formatting and print
Sample 2:
<STX>L<CR>
rTEST<CR>
X<CR>
<STX>G<CR>
Begin label format
Retrieve format named test
Terminate formatting
Print
Sample 3:
<STX>L<CR>
D11<CR>
PO<CR>
SO<CR>
rTEST<CR>
E<CR>
Begin label format
Dot size = 1x1
Print speed O
Feed speed O
Retrieve format named test
Terminate formatting and print
S Set Feed Speed
This command controls the rate at which the label is moved through non-printed areas. The setting
remains unchanged unless another feed speed command is received or until the printer is reset.
Syntax:
Sa
Where:
a
-
I
s a single alpha character representing a speed; see Appendix
L
for valid ranges.
Sample:
<STX>L
SE
141100001000100LABEL1<CR>
E
<STX>L
1411000010001000LABEL2<CR>
E
The sample sets the feed speed to 3 inches per second (76 mmps), and prints two labels. The feed
speed for the second label is the same as the first.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-4310 and is the answer not in the manual?

Datamax A-4310 Specifications

General IconGeneral
BrandDatamax
ModelA-4310
CategoryPrinter
LanguageEnglish

Related product manuals