Page #66 background imageLoading...
Page #66 background image
Figure 65. Installing the rear mounting front PERC module
Next steps
1. Install the drive backplane.
2. If removed, install the air shroud.
3. Install the drive backplane cover.
4. Follow the procedure listed in After working inside your system.
System memory
System memory guidelines
The PowerEdge R6525 system supports DDR4 registered DIMMs (RDIMMs) and Load Reduced DIMM (LRDIMMs). System
memory holds the instructions that are started by the processor.
Your system memory is organized into eight channels per processor (two memory sockets per channel),16 memory sockets per
processor and 32 memory sockets per system.
66
Installing and removing system components

Table of Contents