Chapter 5 Parameters_VFD-B Series
5-58
Revision 10/2005, BE13, SW V4.08
04 - 19
AVI Analog Input Delay Unit: 0.01
Settings 0.00 to 10.00 sec Factory Setting: 0.05
04 - 20
ACI Analog Input Delay Unit: 0.01
Settings 0.00 to 10.00 sec Factory Setting: 0.05
04 - 21
AUI Analog Input Delay Unit: 0.01
Settings 0.00 to 10.00 sec Factory Setting: 0.05
These input delays can be used to filter noisy analog signals.
04 - 22
Analog Input Frequency Resolution
Factory Setting: 01
Settings 00 0.01Hz
01 0.1Hz
It is used to set the unit of the resolution of frequency command when the input source is analog signal.
04 - 04
Multi-function Input Terminal (MI1)
Factory Setting: 01
04 - 05
Multi-function Input Terminal (MI2)
Factory Setting: 02
04 - 06
Multi-function Input Terminal (MI3)
Factory Setting: 03
04 - 07
Multi-function Input Terminal (MI4)
Factory Setting: 04
04 - 08
Multi-function Input Terminal (MI5)
Factory Setting: 05
04 - 09
Multi-function Input Terminal (MI6)
Factory Setting: 06

Table of Contents

Other manuals for Delta VFD185B43A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD185B43A and is the answer not in the manual?

Delta VFD185B43A Specifications

General IconGeneral
BrandDelta
ModelVFD185B43A
CategoryDC Drives
LanguageEnglish

Related product manuals