TECHNICAL REFERENCE MANUAL
5.23.4.3. Synchronous output mode
First, add the Function Generator feature to your channel setup: Click the More… and then select
Function Generator .
In the Function Generator Channel Setup, select channel output mode 1 and now you can select a
synchronous DEWESoft® channel as input 2 . During measurement DEWESoft® will keep a short buffer
of the input channel and then write the buffer to the output channel: i.e. the output channel will be
delayed by about 1 second.